Quick Details
| Place of Origin: | Shanghai China (Mainland) | Brand Name: | HUAWEI | Model Number: | RTN 605 |
| color: | black | package: | carton | Chassis height: | 1U |
| Pluggable: | Not supported | Service interfaces: | E1 | Radio type: | Mini PDH radio,Mini IP radio |
| Number of microwave directions: | 1 |
Specifications
1.Automatic Transmit Power Control
2.Easy Installation
3.Easy Maintenance
2.Easy Installation
3.Easy Maintenance
network equipment MINI PDH/IP radio transmission system HUAWEI OptiX RTN 605
Specifications
The OptiX RTN 605 is a set of Mini radio equipment. It supports one microwave direction, and provides radio tail access solution
The OptiX RTN 605 is of a split structure, consisting of the IDU 605 and the ODU. Each ODU is connected to the IDU 605 through an IF cable.
Introduction to the IDU 605
The OptiX RTN 605 provide a complete ODU solution. OptiX RTN 605 supports the RTN 600 ODU. Generally, the OptiX RTN 605 is configured with the low capacity for PDH ODU. If required in certain special scenarios, the OptiX RTN 605 can also be configured with the standard power ODU.
RTN 600 ODUs supported by the OptiX RTN 605
RTN XMC ODUs supported by the OptiX RTN 605
Configuration model of the OptiX RTN 605
List of the logic boards on the IDU 605
IDU 605
The IDU 605 is the indoor unit of the OptiX RTN 605. It accesses services, performs multiplexing/demultiplexing and IF processing of the services, and provides system control and communication function.Introduction to the IDU 605
| Item | Performance | |
|---|---|---|
| Type | IDU 605 1D/2D | IDU 605 1E/2E |
| Chassis height | 1U | |
| Pluggable | Not supported | |
| Service interfaces | E1 | E1, FE, GE |
| Ethernet processing capability | Not supported |
|
| Radio type | Mini PDH radio | Mini IP radio |
| Number of microwave directions | 1 | |
| RF configuration mode | 1+0 non-protection (IDU 605 1D/1E) 1+1 protection (IDU 605 2D/2E) | |
ODU
The ODU is the outdoor unit of the OptiX RTN 605. It performs frequency conversion and amplification of signals.The OptiX RTN 605 provide a complete ODU solution. OptiX RTN 605 supports the RTN 600 ODU. Generally, the OptiX RTN 605 is configured with the low capacity for PDH ODU. If required in certain special scenarios, the OptiX RTN 605 can also be configured with the standard power ODU.
RTN 600 ODUs supported by the OptiX RTN 605
| Item | Description | |
|---|---|---|
| Low Capacity for PDH ODU | Standard Power ODU | |
| ODU type | LP and LPA | SP and SPA |
| Frequency band | 7/8/11/13/15/18/23 GHz (LP ODU) 7/8/11/13/15/18/23/26/32/38 GHz (LPA ODU) | 7/8/11/13/15/18/23/26/38 GHz (SP ODU) 6/7/8/11/13/15/18/23 GHz (SPA ODU) |
| Microwave modulation mode | QPSK/16QAM | QPSK/16QAM/32QAM/64QAM/128QAM/256QAM (SP ODU) QPSK/16QAM/32QAM/64QAM/128QAM (SPA ODU) |
| Channel spacing | 3.5/7/14/28 MHz | 3.5/7/14/28 MHz |
RTN XMC ODUs supported by the OptiX RTN 605
| Item | Description |
|---|---|
| Low Capacity for PDH ODU | |
| ODU type | XMC-1 |
| Frequency band | 7/8/15/23 GHz |
| Microwave modulation mode | QPSK/16QAM |
| Channel spacing | 3.5/7/14/28 MHz |
Configuration model of the OptiX RTN 605
| Configuration Model | Equipment Type | Type of the IDU | Type of the ODU | Main Application |
|---|---|---|---|---|
| I | Mini PDH radio equipment | IDU 605 1D | Low capacity for PDH ODU | Provides the 1+0 PDH radio link whose capacity is less than 16xE1. |
| II | Mini PDH radio equipment | IDU 605 2D | Low capacity for PDH ODU | Provides the 1+1 PDH radio link whose capacity is less than 16xE1. |
| III | Mini IP radio equipment | IDU 605 1E | Low capacity for PDH ODU | Provides the 1+0 Mini IP radio link with 16xE1 + 2xFE + 2xGE interface. |
| IV | Mini IP radio equipment | IDU 605 2E | Low capacity for PDH ODU | Provides the 1+1 Mini IP radio link with 16xE1 + 2xFE + 2xGE interface. |
Functions and Features
The OptiX RTN 605 provides various functions and features to ensure the quality and efficiency of service transmission.
- Microwave Type
The OptiX RTN 605 supports different microwave types according to the configuration model. - RF Configuration Modes
The OptiX RTN 605 supports the 1+0 non-protection configuration and the 1+1 protection configuration. - Interfaces
The OptiX RTN 605 has various interface types. - Automatic Transmit Power Control
The automatic transmit power control (ATPC) function enables the output power of the transmitter to automatically trace the level fluctuation at the receive end. This technology reduces the interference with neighboring systems and residual BER rate. - Ethernet Processing Capability
The 1E/2E provides powerful Ethernet service processing capability. - Protection Capability
Different IDUs have different protection capacities. - Network Management
The OptiX RTN 605 supports multiple network management (NM) modes, and provides complete NM information exchange schemes. - Easy Installation
The OptiX RTN 605 supports several installation modes. Therefore, the installation is flexible and convenient. - Easy Maintenance
The OptiX RTN 605 provides several maintenance features. Therefore, it can effectively reduce the cost of equipment maintenance.
List of the logic boards on the IDU 605
| Logical Board Name | Full Name | Logical Slot | Description |
|---|---|---|---|
| PW48A | -48 V power board | Slot 1 | Provides two inputs of -48 V DC power. |
| SCC | System control and communication board | Slot 2 | Provides the NMS interface. |
| EOW | Orderwire board | Slot 3 | Provides the synchronous/asynchronous data interface and orderwire interface. |
| PH1 | 16xE1 tributary board | Slot 4 | Provides 16 75-ohm/120-ohm E1 interfaces. The interface impedance can be set by using the software. |
| EM4T | 4-port RJ-45 Fast Ethernet/Gigabit Ethernet switching processing board | Slot 5 |
|
| IF0 | IF board | Slot 8 (IDU 605 1D/1E) Slot 7/8 (IDU 605 2E) |
|
ODU
The
ODU is an integrated system and is of various types. The structures and
working principles of various types of ODUs are the same.
In the transmit direction, the IF signal is processed as follows:
The -48 V DC power signal is sent to the PWR power unit where the secondary power supply of a different voltage is generated and provided to the modules of the ODU.
The O&M downlink signal is modulated under the ASK scheme in the CTRL unit. The 10 MHz signal is generated through the modulation and sent to the multiplexer. The CTRL unit also detects the receive power through the RSSI detection circuit and provides the RSSI interface.
The IF signal and the O&M downlink signal are combined in the multiplexer and then sent to the IDU through the IF cable.
Signal Processing in the Transmit Direction
The multiplexer splits the signal coming from the IF cable into a 350 MHz IF signal, an O&M uplink signal, and a -48 V DC power signal.In the transmit direction, the IF signal is processed as follows:
- Through the up-conversion, filtering, and amplification, the IF signal is converted into the RF signal and then sent to the AMP amplifier unit.
- The AMP amplifies the RF signal (the output power of the signal can be controlled by the IDU software).
- After the amplification, the RF signal is sent to the antenna through the diplexer.
The -48 V DC power signal is sent to the PWR power unit where the secondary power supply of a different voltage is generated and provided to the modules of the ODU.
Signal Processing in the Receive Direction
In the diplexer, the receive RF signal is separated from the antenna signal. The RF signal is amplified in the low noise amplifier (LNA). Through the down-conversion, filtering, and amplification, the RF signal is converted into the 140 MHz IF signal and then sent to the multiplexer.The O&M downlink signal is modulated under the ASK scheme in the CTRL unit. The 10 MHz signal is generated through the modulation and sent to the multiplexer. The CTRL unit also detects the receive power through the RSSI detection circuit and provides the RSSI interface.
The IF signal and the O&M downlink signal are combined in the multiplexer and then sent to the IDU through the IF cable.
0 comments: